M12 Ethernet panel feed-through adapter as a plug-and-play solution for M12 Ethernet interfaces of modern cameras used for video surveillance in trains, so-called railway CCTV systems. Advantages include the connection, which can be plugged in directly within a few seconds, and the functionally reliable, error-free data transmission, as there is no need for assembly work and therefore no possible connection errors.
The M12 HM-Panel Feed Through (PFT) is a rear mountable version, which allows to connect two M12 100 Mbit (Cat5/5e) cables. The PFT can be fixed via thread or counter nut to a cabinet wall, device wall or plate. This makes cabling e. g. through a railway coach easier and it is more comfortable to replace cables in case of services. Advantageous is the pluggability and the use of standard cables. It is now possible to realize cable transfers with fixation.
Technical features
– Compact dimensions, small outer diameter
– Female: M12 D-code / M12 Male: D-code
– Effective shielding achieved by full metal housing
– rear mount version
– fixed (not turnable) M12 locking parts
– Adaptor WAF 19, Counter nut WAF 19
Technische Daten / Technical data |
|
Steckgesicht / Connector mating face |
M12 gemäß / acc. to IEC 61076-2-101 |
Typ-Kodierung-Polzahl / Gender-Coding-No of pins |
Buchse D-4 auf Stift D-4 / Female D-4 to Male D-4 |
Strombelastbarkeit/ Current rating |
0,5 A (Ethernet) |
Bemessungsspannung / Nominal voltage |
48 V (Ethernet) |
Durchgangswiderstand / Contact resistance |
≤ 10 mΩ |
Isolationswiderstand / Insulation resistance |
≥ 100 MΩ |
Überspannungskategorie/ Overvoltage category |
III |
Verschmutzungsgrad / Pollution degree |
3 |
Übertragungsgeschwindigkeit / Data transmission rate |
100 Mbit |
Schutzart / IP protection |
IP 67 (im verriegelten Zustand / in locked condition) |
Temperaturbereich / Temperature range |
–40° C bis/to +105° C |
Mechanische Lebensdauer / Mechanical lifetime |
≥ 250 Steckzyklen / mating cycles |
Verriegelung D-kod. Seite A / Locking screw D-code side A |
nicht drehbar / not turnable |
Verriegelung X-kod. Seite B / Locking screw X-code side B |
nicht drehbar / not turnable |
Drehmoment / torque force |
max. 0,8 Nm (M12 Kabelschraube /M12 cable screw) |
Anzugsmoment / tightening torque |
3 – 4 Nm (counter nut) |
Materialien / Materials |
|
Gehäuse / Housing |
Cu-Legierung vernickelt / Cu alloy Ni plated |
Isolierkörper + Kontaktträger / |
Thermoplast I2/F2 acc. to NFF-16-101/102 and HL3 acc. to R22/R23 EN 45545-2 |
Kontaktmaterial / Contact material |
Cu-Legierung / Cu alloy |
Kontaktoberfläche /Contact plating |
Ni/Au |
Dichtungen / Sealings |
Elastomer |